BGPMV - ACTIVATOR 707 AMPULE, 8112088, 17446
- MSDS: BGPMV
- Manufacturer: LOCTITE CORP
- Product Name: ACTIVATOR 707 AMPULE, 8112088, 17446
- National Stock Number: 8040-01-164-1464
Product Identification
Product ID:ACTIVATOR 707 AMPULE, 8112088, 17446
MSDS Date:01/04/1993
FSC:8040
NIIN:01-164-1464
MSDS Number: BGPMV
Responsible Party
NEWINGTON, CT 06111
US
Emergency Phone: 203-278-1280
Info Phone: 203-278-1280
Preparer: STEPHEN REPETTO
Cage: 7K128
Contractor
Telephone: 860-571-5100
Cage: 05972
Ingredients
7%.
CAS: 71-55-6
RTECS: KJ2975000
Fraction By Weight: 80-85%
OSHA PEL 350 PPM
ACGIH TLV: 350 PPM; 450 STEL
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
BUTANAL-ANILINE CONDENSATE
CAS: 9003-37-6
Fraction By Weight: 10-15%
OSHA PEL N/K
ACGIH TLV: N/K
8%
CAS: 75-65-0
RTECS: EO1925000
Fraction By Weight: 1-3%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM
13.1%
CAS: 109-87-5
RTECS: PA8750000
Fraction By Weight: 1-3%
OSHA PEL 1000 PPM
ACGIH TLV: 1000 PPM
VOLATILE ORGANIC COMPOUND; 82.6%; 802 G/L (LESS EXEMPT
RTECS: 9999999VO
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CHLOROCARBON MATERIALS HAVE PRODUCED
SENSITIZATION OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD
HAVE SIMILAR EFFECT IN HUMANS. ADRENOMIMETICS (EG, EPINEPHRINE) MAY
BE CONTRA-INDICATED EXCEPT FO R LIFE-SUSTAINING USES IN HUMANS
ACUTELY/CHRONICALLY EXPOSED TO CHLOROCARBONS . HEADACHE, (EFTS OF
OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: NAUSEA, DIZZINESS. NARCOSIS AT HIGH
CONCENTRATION.
Medical Cond Aggravated by Exposure:1,1,1-TRICHLOROETHANE: CNS, LIVER,
HEART DISEASE, ALCOHOLISM, SKIN DISORDERS, EYE PROBLEMS,
RESPIRATORY DISORDERS.
First Aid
First Aid:INGEST: DO NOT INDUCE VOMITING. KEEP INDIVIDUAL CALM. OBTAIN
MEDICAL ATTENTION. INHAL: REMOVE TO FRESH AIR. IF SYMPTOMS PERSIST,
OBTAIN MEDICAL ATTENTION. SKIN: FLUSH WITH WATER. EYES: FLUSH
THOROUGHL Y WITH WATER FOR AT LEAST 15 MINUTES. OBTAIN MEDICAL
ATTENTION.
Fire Fighting
Flash Point Method:TCC
Flash Point:NONE
Lower Limits:SEE INGS
Upper Limits:SEE INGS
Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL AND PHOSGENE .
Accidental Release
Spill Release Procedures:ALLOW TO EVAPORATE WITH GOOD VENTILATION. SOAK
UP RESIDUE IN AN INERT ABSORBENT. STORE IN A CLOSED CONTAINER UNTIL
DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE BELOW 110F. AVOID PROLONGED
BREATHING OF VAPOR.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
UV RADIATION MAY CAUSE THE FORMATION OF HCL AND/OR PHOSGENE .
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:PROVIDE ADEQUATE LOCAL VENTILATION TO MAINTAIN VAPOR
CONCENTRATION BELOW TLV.
Protective Gloves:RUBBER OR PLASTIC GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
HCC:T4
Boiling Pt:B.P. Text:175F,79C
Vapor Pres:<100
Vapor Density:4.5
Spec Gravity:1.20 @ 80F
Solubility in Water:SLIGHT
Appearance and Odor:BROWN LIQUID; SHARP ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
SOLVENT MAY REACT VIOLENTLY WITH ALUMINUM ON PROLONGED CONTACT.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:PHOSGENE . TOXIC CHLORIDES.
Disposal
Waste Disposal Methods:FOLLOW EPA FEDERAL, STATE AND LOCAL REGULATIONS
FOR DISPOSAL OF CHLORINATED HYDROCARBONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.